INSTRUCTION SHEET
WARNING
1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer
service representative.
2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3. All instructions must be completely followed to ensure proper and safe installation and performance.
4. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are registered trademarks of ERICO International Corporation
TECHNICAL SUPPORT: PDF121_G 1 of 2 2009,2010,2012,2014 ERICO International Corporation
www.erico.com
LOCK S-Series
Rebar Size
in mm
10 or 12 (#4)
0.57 14.5
14 or 16 (#5)
0.73 18.5
18 or 20 (#6)
0.93 23.5
22 (#7)
1.08 27.5
25 (#8)
1.16 29.4
28 or 30 (#9)
1.32 33.5
32 (#10)
1.48 37.5
34 or 36 (#11)
1.67 42.5
38 or 40
1.83 46.5
43 (#14)
2.07 52.5
57 (#18)
2.62 66.5
Maximum Rebar Shear
Lip Diameter (A)
Figure 1 Assembly cross section
Figure 2 Maximum shear lip
Step 1: Read all instructions and procedures before commencing
splicing. Ensure the LENTON LOCK coupler is sized properly for
the bars being spliced and per project plans. Product should arrive
with bolts configured as shown in Figure 1. One round point bolt
will be on each end of sizes 43(#14) and 57(#18).
LENTON
Figure 3 Solid contact between bar and stop pin as shown.
*When using an air impact wrench it is recommended to use a wrench with double the torque rating identified. Impact sockets should always be used when using an impact
wrench. Additionally, check the air pressure and air flow requirements prior to installation. Refer to complete installation instructions provided with the product or available
at www.erico.com prior to commencing installation.